4105A

•Dust and drip proof.(designed to IEC 529 IP54)
•In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
•Designed to meet IEC 61010-1 safety standard.
•Capable of measuring earth voltage.
•Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
•Small and lightweight. Shock resistant new case material.
•2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.

4106

High test current up to 80mA yielding resolution of 0.001? on 2? range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the “KEW Report” software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.

4200

• The earth resistance from 0.05 to 1500? can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display “NOISE” mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2

Note:
A single earthing can not be measured. (Only for Multiple Earthing System)

4235ER

Microprocessor-controlled.
Earth resistivity (?) test.
Earth testing at 20?, 200?, 2k?.
Earth voltage measuring : 0-300V AC.
Automatic C spike check.
Automatic P spike check.
2-Wire test, 3-Wire test, 4-Wire test.
LCM display.
Auto ranging.
Auto power OFF.
Data hold.
200 measurement results can be saved in the memory and recalled on the display.
Interval between auxiliary earth spikes is 1.0~50.0m.

4305IN

Protection class: IP65 (Lid closed)
• 2 Lines × 16 Characters LCD
• Microprocessor-controlled
• Tests insulation resistance up to 1 T
• 4 Insulation test voltages: up to 5 KV
• AC / DC Voltmeter (30~600V)
• Short-circuit current up to 5mA
• PI (Polarization Index) indication
• DAR (Dielectric Absorption Ratio) indication
• Auto-ranging on all insulation ranges
• Auto-hold function to freeze reading
• Overload protection
• Adjustable testing duration:1~30 minutes
• Internal memory for data storage
• Displays testing duration for insulation measurement
• Auto-off function
• 200 measurement results can be saved in memory and recalled on display

4310IN

Protection class: IP65 (Lid closed)
• 2 Lines × 16 Characters LCD
• Microprocessor-controlled
• Tests insulation resistance up to 2 T?
• 4 Insulation test voltages up to 10KV
• AC / DC Voltmeter (30~600V)
• Short-circuit current up to 5mA
• PI (Polarization Index) indication
• DAR (Dielectric Absorption Ratio) indication
• Auto-ranging on all insulation ranges
• Auto-hold function to freeze reading
• Overload protection
• Adjustable testing duration:1~30 minutes
• Internal memory for data storage
• Displays testing duration for insulation measurement
• Auto-off function
• 200 measurement results can be saved in memory and recalled on display

7016IN

Protection class: IP66 (Lid closed)
Test insulation resistance up to 30T? (30000G?).
Short-circuit current up to 5mA
Microprocessor controlled.
30 insulation test voltages up to 15KV
AC/DC voltmeter (600V).
PI (Polarization Index) indication.
DAR (Dielectric Absorption ratio) indication.
Auto-ranging on all insulation ranges.
Backlight function.
Menu driven.
Visual and audible warning if external voltage is present.
Auto-hold function to freeze the reading.
Overload protection.
Adjustment for testing time (duration) : 1~30 minutes
Auto-off.
Optical USB to RS-232 data transmission.
200 measurement results can be saved in the memory and recalled on the display.
Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 / EN 61326-1

AM-4203HA

ANEMOMETER
Model : AM-4203HA
* -P circuit, 0.4 to 25.0 m/s.
* Max., Min., Memory recall button.
* m/s, ft/min, km/h, mile/h, knots, Temp.(oC/oF).
* Size : 185 x 78 x 38 mm.

CC-423

CURRENT CALIBRATOR
Model : CC-422
* 0 to 24 mA precision current source.
* Range : 0 to 19.99 mA x 0.01 mA. 0 to 24.0 mA x 0.1 mA.

CD 771

  • 3-3/4 digits 4000 count
  • 3-3/4 digits 4000 count
  • Easy to read large LCD with Backlight
  • Large breaking capacity fuse 30kA
  • 1.5V battery check function
  • Thermo plastic elastomer, high resistance  against drop shock
  • Safety cap on current terminal
  • Data hold, Range hold, Relative function
  • Continuity check, Diode test
  • Auto power off function (30min.)
  • Maximum 20A can be measured if the measurement  time is less than 10 seconds. (Take 10 minutes or  longer intervals between measurements)
  • Display : numeral display 4000
  • Sampling rate : 3 times / sec.
  • AC frequency bandwidth : 40〜400Hz (sine wave)

CD 772

  • Double molding with outside made of elastic elastomer material
  • Eye-friendly large-sized display
  • Continuity confirmed by the buzzer and red LED lamp
  • Auto power save: Power save about 30 minutes after no operation
  • Range hold, Data hold, and Relative function â—Large breaking capacity fuse 30kA, Safety cap on current terminal
  • Temperature measurements up to 300 ℃(K type thermocouple temperature sensor

CD 800A

– 3-3 / 4 digits 4000 count
– 0.7% best accuracy
– Capacitance measurement
– Not suitable for measurement of condensers with large leak current.
– Frequency measurement (AC sine wave only)
– Data hold / Range hold
– Relative value
– Auto power off (30min.) (cancelable)
– Low power ohm (input voltage 0.4V) at continuity range
– Solid & protective body cover that can also be used as a tilt stand
– Chip holder behind the body cover
– Display : numeral display 4000
– Sampling rate : 2 times / sec.
– AC frequency bandwidth : 40〜400Hz

Welcome to ACFET

ACFET is a Leading company in the field of Electromechanical Supplying & Contracting was founded in 2013 , based on more than 25 years’ experience in the Egyptian market due to its founders background. Since its born “ACFET” was a very fast grown company depending in that on providing its customers with the high quality products and services and that reflected with a very good reputation in the market and a very strong relation with the customers.